1、 Construction purpose
The construction of automatic monitoring stations for water quality and watershed water environment quality is mainly aimed at real-time monitoring of the water environment quality of key watersheds, rivers, and lakes; Timely prevention of water pollution accidents; Provide a basis for water quality section compliance assessment and ecological compensation. The construction of automatic monitoring stations for water environment quality in the watershed can provide a thorough and real-time understanding of the water environment quality in the watershed.
2、 Construction effect
◆ Improve monitoring efficiency and achieve real-time monitoring effect;
Online query and real-time sharing of water environment quality information;
Timely warning and alarm.
3、 Equipment integration
The automatic monitoring station for watershed water environment quality mainly consists of water collection unit, pretreatment unit, water distribution unit, analysis unit, control unit, information security unit, and other auxiliary facilities.
4、 Construction content
|
class Don't |
Standard Station/Container type station building |
|
Scope of application |
Section compliance assessment, ecological compensation |
|
monitoring factor |
Water temperaturepHDissolved oxygen, conductivity, turbidity, chlorophyllaBlue green algaeCODAmmonia nitrogen, total phosphorus, total nitrogen, permanganate index, heavy metals, biological toxicity, flow rate, total amount, and other special factors, etc |
|
monitoring method |
Water temperature: temperature sensor method PHDifferential electrode method Dissolved oxygen: fluorescence method Conductivity: electrode method Turbidity: Near Infrared Scattering Method CODPotassium dichromate method Ammonia nitrogen, total phosphorus, total nitrogen, permanganate index Heavy metals: spectrophotometric method Biological toxicity: Biological toxicity fish method Traffic: Radar wave online traffic Total amount: Calculation of cross-sectional flux and calculation of watershed total amount |
|
System Features |
1.The station building has a large area, standardized layout, and is easy to manage in a standardized manner; 2.Easy for maintenance personnel, quality control personnel, and on duty personnel to work and rest; 3.Good insulation conditions allow for monitoring of multiple factors; 4.An access control system can be set up to ensure anti-theft security when there is no one on duty; 5.station building/Container design specifications have good lightning and wind protection effects. |
|
name call, name, say, weigh |
model |
description |
|
Online monitoring sensor for five water quality parameters |
YGHB-90 |
Including fluorescence method for dissolved oxygen, electromagnetic conductivity, turbidity,pHTemperature, self-cleaning brush.12~24VPower supply,IP68waterproof1roadRS485Output. |
|
Fluorescence method for dissolved oxygen |
YG-DO |
range0~20mg/Lor0~200%Saturation, accuracy: ±0.3mg/l, Resolution:0.01mg/l,485Interface, waterproof joint,IP68 |
|
Electromagnetic conductivity |
YG-EC |
range:1Ms/cm~600ms/cm, accuracy:<±1.5%,0~1000 uS/cm: 1uS/cm;1 mS/cm~600mS/cm: 0.1 mS/cm, electrode material:PPSheath material:PPSOperating temperature0~100℃,485Interface, waterproof joint,IP68 |
|
turbidity sensor |
YG-TUR |
Fiber optic turbidity, range:0.1~1000NTU, accuracy:<5%or1NTUAccuracy:1NTUResponse time:<2 secSheath material:316LOperating temperature0~50℃,485Interface, waterproof joint,IP68 |
|
PHsensor |
YG-PH |
range0-14PHAccuracy: ±0.01PH, Resolution0.01PHOnline IndustrypHElectrodes,485Interface, waterproof joint,IP68 |
|
temperature sensor |
PTS-3 |
Measuring range-50~+80℃, Resolution:0.1℃, accurate0.1Accuracy: ± |
|
℃ORP |
sensor |
YG-ORPRange: -1500mV~1500mVResolution:1mVAccuracy: ± |
|
6mV |
Suspended solids sensor |
YG-TR0Range:~2000mg/LResolution:0.1NTU0.1, |
|
℃ |
Ammonia nitrogen sensor |
YGDM-NH3N0Range:~10.00mg/LResolution: |
|
0.01mg/L |
Sludge concentration sensor |
YG-MLSS0range~15g/lResolution:0.01g/lAccuracy: ± |
|
5%F.S. |
Residual Chlorine Sensor |
YG-YLRange:0-2.000mg/L(HClO)Resolution: |
|
0.001mg/LCOD |
sensor |
YG-206measurement range:0-100mg/L equiv. KHPResolution: |
|
0.01mg/L |
Chlorophyll sensor |
YG-CHLO0Range:~400ug/LResolution:0.10.1ug/L |
|
, |
℃ |
Blue green algae sensor0YG-BGARange: |
|
— |
300.0Kcells/mL |
Fluoride ion sensor0YG-FLURange:~100mg/L |
|
Resolution: |
0.01mg/L |
Chloride ion sensor0YG-CLIRange:~32000mg/L |
|
Resolution: |
1mg/L |
Potassium permanganate sensorCODMnrange300-2040、50、100、200、500、1000、、 |
|
The |
2000mg/L |
Water depth sensor/ |
Automatic cleaning brush kit, waterproof connector,
If users encounter technical issues that cannot be resolved through phone consultation, our company will respond within 4 hours, and take corresponding measures within 24 hours in the main city and 48 hours in the districts and counties to ensure the normal operation of the equipment.
(3) Technological upgrade
Technical upgrades are within the warranty period. If there are any technical upgrades to the product, our company will promptly notify the user. If the purchaser has corresponding requirements, our company can provide upgrade services.
National Hotline: Official Website: www.jz322.com