The nitrogen oxide converter of Shanghai Jilian Automation Technology Co., Ltd. uses polymer materials as carriers and is loaded with imported catalysts. Under certain temperature conditions, NO2 can be converted into NO. The special design of the converter tube, high-quality catalyst carrier, and stable and reliable temperature control make the converter an ideal tool for nitrogen oxide conversion due to its large catalytic surface area, fast equipment response, high conversion efficiency, and long service life.
The NOx analyzer suitable for air quality monitoring systems and the NOx component measurement of CEMS systems have been widely used in fields such as air quality monitoring, fixed pollution source emission monitoring, and automobile exhaust monitoring.
Introduction to NOX converter functions:
The NO2 → NO converter is used in places where NO analyzers are used to measure NO2 or NOx. This product can convert NO2 in the air into NO. It can also convert NO2 in chimneys, flues, and other pollution sources into NO. As a conversion device before measurement in NDIR infrared absorption nitrogen oxide analysis instruments and chemiluminescence nitrogen oxide analysis instruments, NO2 in total nitrogen oxide NOx (NO+NO2) is converted into NO for measurement, and the concentration of nitrogen dioxide NO2 or total nitrogen oxide NOx is measured.
There are two installation methods to choose from:

Technical parameters of NOX converter:
Model
SS-L
CC-L
Operating Temperature
400℃
300℃
Catalyst material
metal catalyst
carbon-based catalyst
gas flow rate
Max.
90 l/h
work pressure
Max.2
bar abs.warm-up time
≤30min
NO2/NOconversion efficiency
>95%catalyst
NO2/ NOCarbon basedAt a smoke flow rate of30l/h,10vpmNO212,
5Vol%
+10 O2In the case of use
month
Operating Temperature~
+50 °Crelative humidity<
80%
Sample gas injection
/outgoing interface
PVDF
OD6mmInstallation method19”
Rack mounted installation/wall mounted installation optional
power supply
AC220V
±
5% 50HzProtection levelIP